RE-102R / 104 R
Overview
- The RE-102R & RE-104R is a 2 & 4 Zone Fire Alarm Control Panel, which uses conventional input devices. The Outputs include Notification Appliance Circuits (sounders), two programmable Form – C relays, RS-485 port to interface with annunciators and optional zone wise sounder & zone wise contact. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level. Optional ethernet, & GSM ports are user for transmission
- This Fire Alarm Control panel is designed to be used for small size commercial buildings and small-scale industries.
- Special Features
- Tech Specifications
- Downloads
- Certificates
- Tools
- CE Approved.
- 16 X 2 Dot Matrix LCD Display.
- Standby battery backup with built in charging.
- Switch Mode Power Supply.
- Tactile Keypad for easy panel operation.
- System ON indication.
- Low Battery visual warning with audible tone.
- Fire / Fault status in unambiguous colored LED indication.
- 2 programmable relays for fire, supervisory and fault.
- All zones accept smoke detectors and any normally open contact device.
- Any Zone can be configured as alarm or supervisory.
- Zone wise isolation and one man walk test facility.
- Programmable Aux Outputs.
- Lamp test & Drill test facility.
- 100 All Events log with RTC.
- Date / Time / Password configuration.
- Programmable auto silence facility.
- Zone wise sounder / contact (optional).
- TCP-IP / GSM facility (optional).
- All field wiring circuits are supervised.
Electrical Specification
Primary Power 120 / 230VAC + 10% -15%, 60 / 50 Hz, 50W | |
Standby Power 24VDC (2 Nos of 12V, 3.5Ah Sealed Lead acid battery) Quiescent current : 55mA | |
Operating Condition Operating Temperature 0 – 49° C / 32 – 120° F. Storage Temperature 0 – 60° C Relative Humidity 93 ± 2% RH (non-condensing) at 32 ± 2° C / 90 ± 3° F | |
Quiescent Current 2 Zone 4 zone | 40mA 50mA |
Charging Circuit Charging voltage Charging current | 28 V ± 5% 350mA (max) |
24VDC Quantity Voltage Current | 1 No 24VDC continuous or resettable (Regulated) 100mA (max) |
Notification Appliance Circuits Wiring style Quantity Operating voltage Current EOL resistor | Class B 1 No 24VDC (Regulated) 350mA 4K7, 1/2 watt |
Relays Type Quantity Relay contact rating Power factor | Form C 2 No’s (Programmable) 1A @ 30 VDC 1.0 |
Initiating Device Circuits Wiring style Quantity Normal operating voltage Alarm current Short circuit current Loop resistance EOL Resistor Standby Current | Class B 2 or 4 (102R- 104R) 14 – 21 VDC 15 – 35 mA 42 mA (max) 50 Ω (max) 4K7, ½ watt 6.8 mA (2.4 mA for detectors) |
RS 485 Nodes Wiring Style Wire type Circuit Length Loop resistance | 1 Class B Twisted pair 1.2 Km (Max) 100 Ohms |
Mechanical Specification
Dimensions | : | 300L X 200W X 95D |
Wire Size | : | 1.5 Sq mm |
IP rating | : | IP 60 |
Color | : | Black |
Material | : | FRABS plastic |
Cable Entry | : | 11 x ø19mm Knockout on top of the cabinet |
Ordering Information
Model | Description |
---|---|
RE-102R | 2 Zone Fire Alarm Panel |
RE-104R | 4 Zone Fire Alarm Panel |
Compatible Devices
Model | Description |
---|---|
RE-316S-2L | Photoelectric Smoke detector with base. |
RE-316H-2L | Heat detector with base. |
RE-316SH-2L | Photoelectric & Heat detector with base |
RE-716 MR | Conventional Manual Call Point. |
RE-716P1T | Manual Pull station – Single action. |
RE-716P1TLP (R) | Manual Pull station – Dual action. |
RE-25SS | Conventional Sounder cum Strobe |
RE- 24 CS | Conventional Sounder. |
RE-716SO | Conventional Sounder – UL Listed. |
RE-716SO | Conventional Sounder cum Strobe – UL Listed. |
RE-364BS | Conventional Sounder Base. |